| Availability: | |
|---|---|
The BFS-365 stainless steel 316 level sensor is a high-performance device designed for measuring liquid levels, particularly in drinking water applications.
The 8mm miniaturized water level sensor for industrial coolers is a compact and efficient device designed to accurately monitor the water levels in industrial cooling systems. This sensor is specifically designed to fit into tight spaces and provide reliable readings for optimal cooling system performance. With its small size and high sensitivity, this sensor is able to detect even small changes in water levels, ensuring that the cooling system operates at peak efficiency.

The BFS-365 stainless steel 316 level sensor is a high-performance device designed for measuring liquid levels, particularly in drinking water applications.
The 8mm miniaturized water level sensor for industrial coolers is a compact and efficient device designed to accurately monitor the water levels in industrial cooling systems. This sensor is specifically designed to fit into tight spaces and provide reliable readings for optimal cooling system performance. With its small size and high sensitivity, this sensor is able to detect even small changes in water levels, ensuring that the cooling system operates at peak efficiency.

Material:
Constructed from stainless steel 316, this sensor is highly resistant to corrosion, making it ideal for environments exposed to moisture and aggressive substances.
Output Signals:
It typically provides standardized output signals (such as0-190Ω or 240-33Ω), facilitating integration with control systems and monitoring equipment.
Integrating a water temperature sensor into the BFS-365 level sensor is a feasible option and can enhance its functionality.
Material:
Constructed from stainless steel 316, this sensor is highly resistant to corrosion, making it ideal for environments exposed to moisture and aggressive substances.
Output Signals:
It typically provides standardized output signals (such as0-190Ω or 240-33Ω), facilitating integration with control systems and monitoring equipment.
Integrating a water temperature sensor into the BFS-365 level sensor is a feasible option and can enhance its functionality.
| model # | BFS-365 |
| Length | 365mm from the bottom of the head screw |
| Material | PP stem and float |
| Output | 240-33ohm |
| Resolution | 21mm in resolution |
| Float dimension | 26*26 PP |
| Cable length | 250mm without connector: length is customizable |
| NTC internal | at bottom of the inner PCB, to sense liquid temperature |
| model # | BFS-365 |
| Length | 365mm from the bottom of the head screw |
| Material | PP stem and float |
| Output | 240-33ohm |
| Resolution | 21mm in resolution |
| Float dimension | 26*26 PP |
| Cable length | 250mm without connector: length is customizable |
| NTC internal | at bottom of the inner PCB, to sense liquid temperature |
Hydroponics and Greenhouses:
Used to maintain optimal growing conditions by monitoring water levels and temperatures in nutrient solution reservoirs.
Environmental Monitoring:
Suitable for monitoring water bodies in ecological studies, helping track temperature variations that could impact local ecosystems.
Hydroponics and Greenhouses:
Used to maintain optimal growing conditions by monitoring water levels and temperatures in nutrient solution reservoirs.
Environmental Monitoring:
Suitable for monitoring water bodies in ecological studies, helping track temperature variations that could impact local ecosystems.
Installing a level sensor involves several key steps:
Choose the proper mounting Location:
Select an appropriate spot for the sensor where it can accurately measure the water level, avoiding obstructions.
Prepare the Site: Clean the installation area to ensure a secure fit and prevent interference.
Mount the Sensor:
Follow the manufacturer’s guidelines step-by-step to securely mount the sensor.Ensure it works in consistence with pre-defined tank's EMPTY and FULL.
Connect Wiring:
Properly connect the sensor to the power supply and control system, adhering to safety standards. We could put integrated connector in design if needed.
Test the Sensor:
After installation, test the sensor to check&ensure it responds correctly to water level changes.
Calibrate:
If necessary, calibrate the sensor according to the manufacturer’s instructions for precise readings.
Regular Maintenance: Establish a routine to check and maintain the sensor for optimal performance periodically, such as visual inspection and cleansing.
Installing a level sensor involves several key steps:
Choose the proper mounting Location:
Select an appropriate spot for the sensor where it can accurately measure the water level, avoiding obstructions.
Prepare the Site: Clean the installation area to ensure a secure fit and prevent interference.
Mount the Sensor:
Follow the manufacturer’s guidelines step-by-step to securely mount the sensor.Ensure it works in consistence with pre-defined tank's EMPTY and FULL.
Connect Wiring:
Properly connect the sensor to the power supply and control system, adhering to safety standards. We could put integrated connector in design if needed.
Test the Sensor:
After installation, test the sensor to check&ensure it responds correctly to water level changes.
Calibrate:
If necessary, calibrate the sensor according to the manufacturer’s instructions for precise readings.
Regular Maintenance: Establish a routine to check and maintain the sensor for optimal performance periodically, such as visual inspection and cleansing.