Product IntroductionS5 series level sensor hi fluid monitoring dik leh chhunzawm zel theihna tura engineer a ni a, bio-diesel tank leh tunlai generator system tan bik a siam tha a ni. Industrial-in fuel management dik tak a mamawhna a san chhoh zel avangin, operational efficiency vawng reng turin monitoring solution rintlak neih hi a pawimawh hle a ni. He high-resolution sensor hi heng mamawh dik takte phuhrukna tura siam a ni a, continu
Availability:
facebook ah in share theih a ni
twitter hmanga share theih a ni
line insem theihna button a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp a insem theihna tur a ni
sharethih hi share theih a ni

S5 series level sensor hi fluid monitoring dik leh chhunzawm zel theihna tura engineer a ni a, bio-diesel tank leh tunlai generator system atan a bik takin siam a ni. Industrial-in fuel management dik tak a mamawhna a san chhoh zel avangin, operational efficiency vawng reng turin monitoring solution rintlak neih hi a pawimawh hle a ni. He high-resolution sensor hi heng mamawh dik takte phuhrukna tur atana siam a ni a, power siam chhuah chhunzawm zel leh fluid dahkhawmna himna tur support turin fluid level tracking method nghet leh dik tak a pe a ni.

Resolution sang tak 4-20mA Current Output a ni

He device-a thil langsar tak pakhat chu S5 series level sensor hian 4-20mA output a pe a, generator system awm tawhte nen pawh awlsam takin a inzawm khawm a, fuel level data dik tak a pe chhuak thei a ni. He high-resolution signal hian data transmission-ah dikna danglam tak a pe a, bio-diesel reserve chiang taka enfiah theih a ni. 4-20mA output hian transmission distance rei takah electrical noise leh signal degradation a do thei hle a, hei vang hian complex industrial facility tan chuan duhthlanna tha tak a ni. Control panel-te nena inzawm tlat a nih theih nan he sensor hian operator-te chu real-time, rintlak fuel level data an dawng thei tih a tichiang a, proactive maintenance a siam thei a, beisei loh taka downtime a awm loh nan a pui bawk.

Protenuous Measurement atan Float Mechanism rintlak tak a awm

Sensor rintlakna bulpui ber chu a taksa design finfiah tawh hi a ni. Fuel level nena inmil float mechanism a nei a, hei hian tehna chhunzawm zel leh rintlak tak a siam thei a ni. Sensing technology dang, fluid bik-a signal interference emaw false reading emaw tuar thei ang lo takin, he mechanical stability hi bio-diesel tank-ah chuan a hlu hle. Continuous tracking capability hian facility manager-te chuan an fuel inventory chungchangah dik tak, real-time-a hriatthiamna an nei reng tih a tichiang a, hei hian resource planning tha zawk leh operational security tha zawk a siamsak a ni.

Installation leh Maintenance tihchangtlun a ni

Deployment-a efficiency hi hmanrua tihchangtlunna leh installation thar siamna atana thil pawimawh tak a ni. He sensor atan hian installation hi a awlsam a, tank chunglam atanga SAE-5 hole flange dah a ni. He industry-standard mounting method hian equipment downtime a ti tlem a, sensor chu infrastructure awmsa nena inzawmkhawmna a ti tlem bawk. Top-mount design hian initial setup a ti awlsam mai bakah nakin lawka inspection leh maintenance pawh nasa takin a awlsam phah a, hun rei tak chhunga value a pe a, facility operator-te tan labor cost zawng zawng a tihtlem phah bawk.

Bio-diesel leh Generator hmanna atana tha zawka siam a ni

S5-350 level sensor hmanna value hi basic measurement aiin a zau hle. Bio-diesel dahkhawmna leh generator power system chungchangah chuan fuel enfiahna dik tak chu hnathawh chhunzawm zelna atan a pawimawh hle. Bio-diesel storage tank leh generator control system inkara interface rintlak tak a siam avangin he sensor hian fuel hman dan a ti tha thei a, fuel tlakchham vanga power chhiatna nasa tak a veng thei a, power generation infrastructure pumpui efficiency a pui bawk. Facility-te tana an fluid management theihna tihpun leh power supply chhunzawm zel, rintlak tak neih theihna tura ruahman, strategic component a ni.

S5-350 high-resolution float level sensor technical parameters te chu a hnuaia mi ang hian chipchiar takin tarlan a ni a, hei hian bio-diesel tank application atana procurement dik tak leh system integration a pui thei dawn a ni. He data sheet hian hmanrua thlan chhuahna atana pawimawh tak tak physical dimension, electrical output, leh material specification te a tarlang a ni. Project mamawh bik phuhrukna tura siam probe leh cable sei zawng atana customizable range te kha hre reng ang che.

Entawn tlak # S5-350 ah a awm
Dung Head unit hnuai lam atanga a sir thlengin 350mm a ni a, 110mm~3000mm hi customizable a ni
Bungrua stainless steel probe leh NBR float hmanga siam a ni
Output a ni 4-20mA thleng a ni
Thutlukna 21mm a ni (default) a ni.
Float dimension a ni 35*32 NBR a ni
Mounting a ni SAE-5 hole flange a ni
Cable sei zawng a ni default sei zawng chu connector tel lovin 460mm a ni a; a sei zawng chu customizable a ni

Customization Capabilities: Equipment setup hrang hrang nena seamless integration neih theih nan S5-350 sensor hian flexible manufacturing options a support a ni. Stainless steel probe sei zawng hi bio-diesel tank thuk hrang hrang awm theihna turin 110mm leh 3000mm inkarah a bik takin siamrem theih a ni a, cable sei zawng erawh chu i wiring leh installation environment bik nena inmil turin siam theih a ni thung. Heng adaptable parameters te hian fluid level monitoring dik tak leh industrial application hrang hranga 4-20mA signal transmission rintlak tak a tichiang a ni.

Installation & Operation chungchanga kaihhruaina

S5-350 4-20mA current output level sensor dahnaah hian bio-diesel tank tehna dik tak leh hun rei tak chhunga hnathawhna hmun nghet tak neih theihna turin step pawimawh engemaw zat a awm a ni. A hnuaia instruction te hi zawm tur a ni:

  • Step 1: Mounting Location dik tak thlang rawh

    Sensor atan tank-ah hmun remchang thlang la, chutah chuan liquid level dik taka a teh theihna tur hmun thlang rawh. Stainless steel 304 probe chu tank wall, agitator, fluid inlet atanga mechanical interference awm lovin vertical-a tla thei turin enfiah rawh.

  • Step 2: Site chu buatsaih rawh

    Installation hmun chu uluk takin tifai rawh. Mounting hole chhehvela bawlhhlawh, grease emaw, a awm zawng zawng emaw chu paih chhuak la, a fit tha thei ang bera siam la, measurement interference a awm loh nan, leh leak awm thei laka seal dik tak vawng reng rawh.

  • Step 3: Sensor chu mount rawh

    Sensor hi him taka dah theih nan a siamtu kaihhruaina step by step-in zawm rawh. Float leh probe assembly chu uluk takin tank chhungah dah rawh. 4-20mA scaling dik tak neih theih nan tank-a EMPTY leh FULL position ruat lawk nen a inmil taka installation chu a thawk tih enfiah rawh.

  • Step 4: Wiring connect rawh

    Sensor chu i power supply leh control system-ah uluk takin connect la, standard industrial safety protocol zawm rawh. 4-20mA loop wiring chu polarized dik tak a nih leh nih loh enfiah rawh. Field deployment chak zawk nan a tul chuan design-ah integrated connector kan dah thei.

  • Step 5: Sensor chu test rawh

    Install zawhah sensor chu test la, liquid level inthlak danglamnaah a chhanna dik tak a pe tih enfiah leh enfiah rawh. Float chu probe zawh ruala a kal zel chuan output signal chu 4mA (empty) leh 20mA (full) inkarah awlsam takin a inthlak tih finfiah rawh.

  • Step 6: Enkawl reng tur

    Sensor chu a thawh that theih nan a hun hunah enfiah leh enkawl dan tur routine siam rawh. Float chu zalen taka a kal theih nan visual inspection neih a, stainless steel probe-a bio-diesel sludge emaw particulate buildup emaw awm zawng zawng paih chhuah nan cleansing tih.

Zawhna zawh fo thin (FAQ) .

Q1: Liquid level sensor hi eng nge ni a, engtin nge a hnathawh?

A1: Liquid level sensor hi industrial device a ni a, tank emaw container emaw chhunga liquid awm zat hriatchhuah leh tehna atana hman a ni. S5-350 model-ah chuan magnet awmna buoyant float hmangin hna a thawk a ni. Float chu probe-a liquid level nena a san emaw a tlahniam emaw chuan internal components a trigger a, connected display gauge, PLC emaw control system-ah 4-20mA electrical signal chhunzawm zel a pe chhuak thin.

Q2: Engtin nge ka application atan liquid level sensor dik tak ka thlan theih ang?

A2: Liquid level sensor dik thlan tur chuan liquid chi (eg, bio-diesel, corrosive fluids, emaw tui in tur), material mamawh inmilna (Stainless Steel 304 ang chi), tehna dik duh zawng, tank size leh shape, leh installation mamawh bik te ngaihtuah rawh. Output signal type (4-20mA ang chi) pawh i monitoring system nen a inmil tur a ni. Selection chungchang chipchiar tak leh customized solutions hriat duh chuan kan technical team te hi zawhfiah theih a ni.

Hma chiah: 
Dawtchiah: 

A kaihhnawih thil siam

Designer leh level-sensor leh float-switch siamtu zingah top-rated a ni
Subscribe rawh

Quick Links te pawh a awm

Thil siam chhuah te

Industry hrang hrangte

Min rawn biak theih reng e

No. 1, Hengling, Tiansheng dil, Roma, Qingxi khawpui, Dongguan khawpui, Guangdong Province , China-ah a awm a ni
Message pakhat hnutchhiah rawh
Min rawn biak theih reng e
Tel: +86 186 7515 2690 ah
zawhfiah theih a ni. sales@bluefin-sensor.com
WhatsApp: +86 186 7515 2690 ah zawhfiah theih a ni
 
Copyright © 2024 Bluefin Sensor Technologies Limited Thuneihna zawng zawng humhalh a ni. Sitemap a ni | Thuruk humhalh dan tur