Please Choose Your Language
In » Blog 100 a ni. » Industry chanchin thar . » Side-Mount High Level Switches: Side entry chu duhthlanna dik a nih chuan

Side-mount High Level Switches: Side entry chu duhthlanna dik a nih chuan .

A rilru a buai em em a, a rilru a hah em em 0     bawk a, a rilru a buai em em bawk a. Hmun

zawhna zawt rawh .

Facebook Sharing button a awm bawk.
Twitter atanga Sharing button a awm bawk.
Line Sharing button a awm bawk.
WeChat hmanga Sharing tih a ni.
LinkedIn Sharing button a awm bawk.
Pinterest hmanga Sharing tih a ni.
WhatsApp Sharing button 1000 a awm bawk.
Kakao Sharing button a awm bawk.
Snapchat Sharing button a awm bawk.
Telegram hmanga Sharing tih a ni.
ShareHe Sharing button hi a awm em?
Side-mount High Level Switches: Side entry chu duhthlanna dik a nih chuan .

Side-mount sang tak a ni. Level switch  hi tank shallow, limited top access, emaw retrofit installation te chuan top-mount device hmanlai a tih theih loh nan hmanna atana solution tha tak a ni. Bluefin Sensor Technologies Limited, top-rated designer leh level sensor leh float switch siamtu chuan industrial leh HVAC system-a performance rintlak tak neih theihna tura siam side-mount level switch hrang hrang a pe a ni. Heng switch te hnathawh dan hriatthiamna, engtikah nge thlan tur tih te, leh installation atana best practices te hian high-level detection dik tak a siam thei a, chutih rualin nuisance trip leh system interruption te pawh a veng thei bawk. Chu bakah, heng hmanrua te hi engineer-in a siam a, hun rei tak chhunga rintlakna pe theiin boruak khirh tak takah pawh fluid property, temperature, emaw tank geometry te chuan standard top-mount installation a ti buai thei a ni.

 

Side-mount high level switch tih hi eng nge ni?

Side-mount High Level Switches hi float-type device a ni a, a chung lam aiin tank sir lamah dah a ni. Top-mount level switch ang lo takin, tank chunglam atanga vertical-a dah a ni a, side-mount switch te chu horizontal emaw angle tlemte emawa dah a ni a, space constraints awm theihna tur a ni. He design hi retrofit, tank vertical space khap tlat, emaw, top-mount device-in hmanraw dang emaw, piping emaw a tihbuai theihna tur, shallow vessel-te tan a tangkai hle.

Construction leh Sensing danglamna .

Side-mount leh top-mount switch inkara danglamna ber chu sensing mechanism leh orientation-ah a awm a ni. Side-mount switch-ah chuan stem emaw cage emaw-a float inbun a hmang a, chu chu liquid a san chuan pivot emaw slide emaw a ni. Hetianga a kal hian internal mechanical emaw magnetic switch emaw a tichhuak a, high-level alarm signal a pe a ni. Float hi horizontal emaw angle-a hnathawh a nih avangin turbulence leh vibration hian installation chhunga account dik lo a nih loh chuan performance a nghawng thei a ni. Chumi danglamna chu top-mount switch te hian gravity-assisted vertical float motion an rinchhan a, hei hian liquid agitation a tuar thei zawk a ni. Side-mount design-ah hian reinforced stems, sealed magnetic couplings, emaw adjustable floats te chu sensitivity tihsan nan leh fluid density inthlak danglamnain a nghawng a tihziaawm avangin industrial liquid hrang hrang, tui leh chemical atanga light fuel thlenga hman a tha hle.

Typical form factors leh mounting option te .

Side-mount level switch te hi form factor hrang hrang a awm a, chung zingah chuan single- emaw dual-stem design leh float cage configuration hrang hrang te tank diameter leh fluid property te nen a inmil a ni. Boss mounting hi a size leh thread type a inang lo thei a, supplier tam tak, Bluefin Sensor Technologies Limited te pawhin tank hawnna awmsa nena inmil tur option tam tak an pe bawk. Form factor dik tak thlan hian float travel dik tak leh high-level detection dik tak a siam a, a bik takin shallow tank emaw retrofit application-ah chuan installation space constrained-naah a awm a ni. Tin, design thenkhatah chuan modular cage emaw, removable floats emaw an pe a, tank chu a chhuah vek ngai lovin tihfai leh enkawl awlsam zawk nan an hmang bawk.

 

Engtikah nge side-mount 1000 aia tam thlang tur a ni.

Side-mount leh top-mount high level switch inkara thutlukna siam chu tank geometry, access limitation, leh retrofit mamawhnaah a innghat a ni.

Side-mount installation atana hman tur scenario tha tak tak a awm bawk.

Side-mount switch te hi vertical clearance tlemna hmunah chuan shallow tank tan a tha hle a, a nih loh leh pre-drilled boss pakhat nei tank awmsaah retrofitting a awm chuan a tha hle. Piping, ladder, emaw hmanraw dang emaw hmanga top access an tihbuai theihna system-ah pawh an hlu hle. Side-mount device install hian installation complexity leh cost a tihtlem bakah high-level detection rintlak tak a vawng reng thei bawk. Engineer-te chuan retrofit project-ah side-mount solution an duh zawk fo a, a chhan chu installation hi tank emaw piping layout awmsaah pawh siamthatna lian tham awm lovin tihfel theih a ni tlangpui.

A hman dan tlangpui .

Side-mount high level switch hmanna tlangpui chu small day tank, HVAC basins, condensate return system, leh reservoir te a ni. Industrial water system-ah chuan side-mount switch-te hian piping emaw maintenance access tibuai lovin high-level alarm signal rintlak tak tak an pe a ni. Fuel dahna emaw pumping system-ah chuan side-mount installation hian retrofits a ti awlsam thei a, chutih rualin alarm setpoint dik tak a vawng reng thei bawk. Chemical dosing tank-ah te pawh an hmang a, chutah chuan hmun a tlem a, liquid agitation chuan a nih loh chuan top-mounted device-ah false alarm a thlen thei a ni. High-level signal dik tak pek a nih chuan, side-mount switch te hian overflows venna, pump chhiatna, leh a tul lo system shutdown te a veng thei a ni.

 Level switch a awm bawk.

Installation dik ber hriat theihna tur atana tih dan tha ber .

Side-mount high level switch te dik taka dah hi alarm dik lo venna tur leh hun rei tak chhunga rintlak a nih theih nan a pawimawh hle.

Mounting san zawng leh orientation .

Mounting san zawng chu alarm setpoint duh leh liquid characteristics duh dan atanga uluk taka chhut tur a ni. Float cage chu a tum aia sang emaw, a hnuai lam emawa dah chuan liquid turbulence leh minor level fluctuation te a awm thei a ni. Orientation pawh a pawimawh ber a; Float chu tank wall emaw internal components emaw a tlak loh chuan zalen takin a kal tur a ni a, a stem chu beisei ang liquid surface angle nen a inmil tur a ni. Design thenkhat chuan install chhunga angle adjustment te chu fine-tune switch sensitivity ah an phalsak a, premature emaw delayed alarm emaw a awm theihna a ti tlem bawk.

Anti-vibration leh turbulence ngaihtuah tur .

Pumping sump-a side-mounted switch, condensate system, emaw, fluid agitation nei fo tank-ah chuan anti-vibration mount emaw shield emaw dah tur a ni. Hei hian splashing emaw vibration-induced float motion avanga nuisance trip awm theihna a ti tlem a ni. Guide stem hmanga float cage hman emaw, stabilizing vane emaw chuan turbulent condition-a stability leh signal accuracy a ti tha lehzual thei. Tin, tank chhunga baffle emaw flow diffuser emaw dah hian float bula liquid stabilize a pui thei a, inflow emaw pumping rates danglam thei system-ah pawh consistent response a tichiang thei bawk.

 

Common failure modes leh invenna enkawlna .

Side-mount switch rintlak ber pawh maintenance ngaihthah a nih chuan harsatna a tawk thei.

Typical harsatna .

Debris atanga blockage, float binding, leh material degradation te hi common failure mode a ni. Thil chhe hian float chu zalen takin a kal thei lo a, corrosion emaw chemical attack emaw chuan switch mechanism a tichhe thei bawk. Rubber emaw plastic float emaw chu hun kal zelah a tlahniam thei emaw, a chhe thei a, a bik takin tui lum emaw, chemical hmanga chemte emaw a ni thei. Environmental factors te, hun rei tak chhunga UV exposure emaw humidity sang tak emaw te hian pawn lam component te pawh a tichhia thei bawk.

Inspection leh invenna tur ruahmanna siam .

Float, stem leh cage te enfiah fo a pawimawh hle. Device tihfai te, obstruction awm leh awm loh enfiah te, leh liquid teh mek nena float density range te finfiah hian hlawhchhamna a veng thei a ni. Bluefin Sensor Technologies Limited chuan a hunbi neia hman theih turin a hunbi neia calibration leh thlak danglam a rawt a, chu chuan hnathawh rintlak tak a neih theih nan a hmang thei ang. Preventive maintenance schedule kalpui hian side-mount switch-te service life nasa takin a ti rei thei a, a bik takin high-use industrial emaw HVAC system-ah chuan.

 

Supplier te tan specification checklist .

Side-mount high level switch i thlan dawnin i supplier nena verify tur key specification a awm a:

Boss size leh thread type i tank nena inmilna .

Industrial emaw hlauhawmna hmun bik atana phalna pek .

Float density range 1000 a hman theih tur a ni.

Spare cages emaw replacement floats awm theihna .

Heng specification te hi i system mamawh ang zela ensure hian installation issue a ti tlem a, tank system nun chhunga switch reliability a ti sang bawk. Thil dang ngaihtuah tur chu electrical rating, switch output type (mechanical, reed, emaw solid-state), leh temperature tolerance te enfiah a, a hman tum nen a inmil theih nan a ni.

 

Tawpna

Side-mount High Level Switches hian  tank thuk lo tak tak, retrofit installation, leh top access tlemte awmna space te tan solution tha tak a pe a ni. Bluefin Sensor Technologies Limited hian switch quality sang tak tak a pe a, chu chuan high-level detection dik tak a pe a, chutih rualin nuisance trip a ti tlem bawk. I side-mount switch uluk taka i thlan, i install leh i enkawl chuan, tui, fuel, emaw industrial fluids te chu tank configuration harsa ber ber pawha enfiah dik tak i siam thei ang. I side-mount high level switch-a installation support dil emaw, i system-te him leh tha taka thawk turin vawiin hian min rawn biak la, i side-mount high level switch-ah installation support i dil ang.

A rilru a buai em em a, a rilru a hah em em bawk a. Level-sensor leh float-switch

Quick Links .

thil siam chhuah te .

Industry hrang hrangte .

Kan rawn biak theih reng e

No. 1, Hengling, Tiansheng Lake, Roma, Qingxi khawpui, Dongguan khawpui, Guangdong Province , China
Message pakhat dah la .
Kan rawn biak theih reng e
Tel: +86- 18675152690
Email: A rilru a hah lutuk chuan a rilru a buai em em a, a rilru a hah lutuk chuan a rilru a buai
em em bawk a. 18675152690
Skype: chris.wh.liao
Copyright © 2024 Bluefin Sensor Technologies Limited A rilru a hah lutuk chuan a rilru a buai em em a, a rilru a hah lutuk chuan a rilru a buai em em bawk a. Sitemap 100 a ni. | Privacy policy 1.1.