Please Choose Your Language
In » Thil siam chhuah te » Smart Level Sensor te a awm bawk » 4-20mA a chhuak thei » S5-400 21mm Resolution 4-20mA Level Sensor a ni a, Generator/genset Tank atan Integrated PCB a awm bawk

S5-400 21mm Resolution 4-20mA Level Sensor a ni a, Generator/genset Tank atan Integrated PCB a awm bawk

Product Introduction S5 series of fuel level sensor hi fuel monitoring rintlak leh chhunzawm zel theihna tura engineer a ni a, generator leh genset tank hmanna atana ruahman bik a ni. Power generation-a fuel management dik tak mamawhna pawimawh tak ngaihtuahin, he sensor hian stable current (4-20mA) output signal a pe a ni. Industrial procurement leh system engineer tan chuan 4-20mA standard hian signal integrity-ah advantage lian tak a entir a ni. Voltage-based signals ang lo takin
Availability degr thei:
facebook ah in share theih a ni
twitter hmanga share theih a ni
line insem theihna button a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp a insem theihna tur a ni
sharethih hi share theih a ni


S5 series of fuel level sensor hi fuel monitoring rintlak leh chhunzawm zel theihna tura engineer a ni a, generator leh genset tank hmanna atana ruahman bik a ni. Power generation-a fuel management dik tak mamawhna pawimawh tak ngaihtuahin, he sensor hian stable current (4-20mA) output signal a pe a ni. Industrial procurement leh system engineer tan chuan 4-20mA standard hian signal integrity-ah advantage lian tak a entir a ni. Facility lian tak takah chuan cable run rei tak avanga degrade thei voltage-based signal ang lo takin, current output hian fuel level data chu tank atanga remote control panel thlengin a dik hle tih a tichiang a ni. Hei hian generator control unit, PLC, leh remote monitoring system awm tawhte nena inzawmna dik tak a siamsak a, operator-te chuan beisei loh taka power tihtawp hlauhawmna awm lovin fuel level ṭha ber an vawng thei a ni.

Continuous Measurement atan Float Mechanism rintlak tak a awm

Power supply kalpui chhunzawm zel tur chuan fuel tehnaah inmilna hi a pawimawh ber a ni. Heng sensor te hian magnetic float mechanism finfiah tawh, integrated PCB hmanga thuam an hmang a ni. Genset tank chhunga fuel level a inthlak danglam chuan float chu a insiamrem a, a chhunga component te chu a trigger a, real-time, continuous measurement a pe thei a ni. He mechanical leh electronic synergy hian sensing technology nghet lo zawk nena inzawm fo thin erratic reading te chu a veng thei a ni. Direct contact float design hmangin S5 series hian monitoring system-in data mumal tak a dawng tih a tichiang a, hei hian facility manager-te chu a hun taka fuel pek hun tur a ruahman thei a, fuel riltam vanga generator downtime man to tak tak a veng thei bawk. Mechanism tangkai tak hian maintenance mamawh tlem zawk leh industrial environment harsa takah operational lifespan rei zawk a thlen a ni.

Versatile Resolution duhthlan tur: 7mm, 10mm, leh 21mm te a ni

Generator tank leh monitoring system hrang hrangte hian measurement granularity degree hrang hrang an mamawh tih hrethiamin, 7mm, 10mm, leh 21mm-a resolution duhthlan tur an pe a, precision mamawh hrang hrang a phuhruk a ni. He S5-400 model bik hian 21mm resolution a nei a, hei hi standard leh large-capacity generator tank tan strategically design a ni. 21mm resolution hian monitoring dikna leh cost-efficiency inkara balance tha tak a pe a ni. Heavy-duty genset application tam takah chuan macro-level fuel consumption tracking hi millimeter-by-millimeter tracking aiin a pawimawh zawk. 21mm step hian operator-te chu active generator hnathawh laiin fuel sloshing emaw engine vibrations avanga micro-fluctuation tul lo tak tak hmanga control system-a tihbuai lohvin fuel level update chiang tak, actionable tak tak an dawng thei a ni.

Procurement leh Operational Efficiency atana siam that a ni

Fuel level sensor dik thlan hi thutlukna pawimawh tak a ni a, hei hian backup leh primary power system rintlakna zawng zawng a nghawng a ni. S5-400 21mm resolution sensor hian genset fuel monitoring-a core pain points te chu a address a, 4-20mA output-a long-distance transmission stability leh float-based measurement system-a structural dependability te chu a thlunzawm a ni. Purchasing manager leh technical buyers tan chuan hei hian tuna architecture awm mekte nen pawh theihtawp chhuah lovin a inzawm mai bakah operational failure risk nasa takin a tihtlem thei component neih tihna a ni. Integrated PCB design hian internal circuitry a ti awlsam a, failure point awm thei te chu a ti tlem zual sauh a, i power generation hmanrua te chu a tul apiangin a inpeih reng a, a fuel kim vek tih a tichiang bawk.

colgroup> a ni
entawn tlak # S5-400 thleng a ni
Dung Head unit hnuai lam atanga a sir thlengin 400mm a ni a, 110mm~3000mm hi a customizable bawk
Bungrua stainless steel probe leh NBR float hmanga siam a ni
Output a ni 4-20mA thleng a ni
Thutlukna 21mm a ni a, a resolution (default) a ni.
Float dimension a ni 35*32 NBR a ni
Mounting a ni SAE-5 hole flange a ni
Cable sei zawng a ni default sei zawng chu connector tel lovin 460mm a ni a; a sei zawng chu customizable a ni

S5-400 level sensor hi industrial environment harsa tak takte mamawhna khauh tak phuhruk turin uluk taka siam a ni. Loop-powered 4–20mA level transmitter anga design a nih avangin liquid height variation te chu efficient takin current signal robust leh stable takah a chantir thei a ni. He standardized electrical output hian tunlai control system nena inzawmna mumal tak a siam a, signal chu km 1 thlenga hla takah noise-free-in a kal thei a, hei hian tank monitoring setup complex tak tak leh industrial procurement mamawhna nasa tak atan duhthlanna rintlak tak a ni.

Sensor chhungah hian precision piezo-resistive emaw magnetostrictive core a awm a, hei hian tehna rintlak leh chhanna danglam tak a tichiang a ni. 304 emaw 316 stainless steel probe chhe thei lo chhungah him takin dah a ni a, corrosion, mechanical wear, leh fluid impact laka invenna tha tak a pe a ni. IP67-rated sealing nen a inzawm chuan, a chhunga electronic component-te hi leivut leh tui lut laka a him tawk a, boruak khirh tak karah pawh hun rei tak chhunga hnathawh theihna a tichiang a ni.

Engineer leh procurement professional-te tan chuan data dik tak lakkhawmna lama innghatte tan chuan he model hian ±0.25 % FS dikna mak tak a pe a ni. Chubakah, optimized electrical design hian zero level-ah 4 mA aia tlem a draw a—chu chuan process resolution dik tak atan 20 mA span kimchang a awm ta a ni. Customization theihna zau tak—probe sei zawng 110mm atanga 3000mm leh adaptable cable configuration te nen—S5-400 hian project leh hmanrua bik mamawh ang zela siam, technical solution versatile, rintlak tak a pe a ni.

Hma chiah: 
Dawtchiah: 

A kaihhnawih thil siam

Designer leh level-sensor leh float-switch siamtu zingah top-rated a ni
Subscribe rawh

Quick Links te pawh a awm

Thil siam chhuah te

Industry hrang hrangte

Min rawn biak theih reng e

No. 1, Hengling, Tiansheng dil, Roma, Qingxi khawpui, Dongguan khawpui, Guangdong Province , China-ah a awm a ni
Message pakhat hnutchhiah rawh
Min rawn biak theih reng e
Tel: +86 186 7515 2690 ah
zawhfiah theih a ni. sales@bluefin-sensor.com
WhatsApp: +86 186 7515 2690 ah zawhfiah theih a ni
 
Copyright © 2024 Bluefin Sensor Technologies Limited Thuneihna zawng zawng humhalh a ni. Sitemap a ni | Thuruk humhalh dan tur